Liquefied Gas Tanker truck(LPG truck)is also known as liquefied gas tanker truck and LPG transport vehicle. It is used to transport propane, propylene, two methyl ether, liquid ammonia, methylamine, acetaldehyde and other liquefied gas. Well, what is rerulation of loading and unloading of LPG truck?


Working process
(1) Check the LPG truck before entering the station to check whether it is equipped with fireproof cap, and whether the gauge is overloaded. There is no leakage in the LPG truck. Safety attachments and vehicle conditions are required for loading and unloading. Driver and escort left communication tools and fire.

 

(2) Parking lot
2.1 speed should not exceed 5 km / h. Pull up the brake according to the location of the indicator. 2.2 of the parking command is completed by the escort.
2.3, when the position is stopped, use the skid block to block the wheels on both sides to prevent the tanker from sliding. At the gate of the

2.4 site, a warning sign for "unloading vehicle not to approach" is set up at the gate. Prepare

 

(3) Before unloading and check
3.1 The LPG truck pressure gauge is confirmed to be normal. Connect the electrostatic grounding wire with It
3.2 liquid phase and gas unloading hose are connected and checked for leaking.
3.3 Inspect the station's facilities and parameters according to the inspection items.

 

(4) Operation process of loading and unloading truck
4.1, first of all, start the PLC power supply and turn on the computer. Open emergency shutoff valves for tanks requiring unloading fluid.

 4.2, then go to the field to open the nitrogen cylinder valve, then the emergency shut-off valve opens.

4.3 open the unloading pipeline valve and retain the tank valve for final control.

4.4. change the loading and unloading valve group to the compressor room. (note that the valve should be opened slowly when the valve is switched on and the compressor valve is opened. Because when the pressure is too high, the flow velocity is too fast, and the equipment is damaged.
If the pressure of the tank car is more than 0.3MPA above 0.3MPA, the compressor and the gas phase valve of the tank car start to open the compressor when the pressure is low or the flow rate is slow.


(5) Compressor operation flow
5.1 check whether the compressor lubricants are within the specified limits. The oil level is between the two scales of the oil scale.

5.2 check whether the valves on the compressor piping and system are in the correct position.

5.3 check whether the connection of various parts of the unit is loose, and whether the belt tightness is suitable.

5.4, open the collector drain valve and drain the liquid.

5.5 start the compressor to observe the vibration and sound of the unit. If there is an abnormality, stop checking immediately. No problem will be allowed. It
5.6 check the compressor inlet and outlet pressure temperature is normal. When the liquid is reversed, the compressor inlet and discharge pressure difference and
The temperature difference is small. When the residual gas is extracted, the pressure difference and temperature difference between intake and exhaust will gradually increase. nothing
In what state, the exhaust temperature of the compressor should not exceed 170 degrees C, and the intake pressure must not be negative.
Pressure or no pressure.
5.7 check whether compressor bearing position and motor temperature are normal. 
5.8, check whether there is gas in the body, if the nozzle takes the gas to the outside. 
5.9 check whether there is leakage in the unit and piping, if there is a shutdown, no compressor is allowed under the condition of leakage.
5.10.After loading and unloading, the compressor must be shut down and the front valve of the compressor should be cut off. Turn off the loading and unloading LPG truck in turn.
Conversion valve group and pipeline valve. Finally remove the gas-liquid hose and grounding wire of the loading and unloading LPG truck.
5.11 monitoring the emergency shut-off valve after the tanker is discharged from the station. Check the site for leakage, fill in the tank loading
Unload the record table. The homework is finished.

 


CHENGLI SPECIAL AUTOMOBILE CO., LTD . is looking forward to your visiting. The reliant quality, excellent service and reasonable price are the promise we keep.

PRODUCT INQUIRY

Contact Us

Add Chengli Automobile Industry Park, Suizhou City, Hubei Province, P.R.China
Office:  7th Building, No. 299 Huaihai Road, Wuhan, China
Email info@clwvehicle.com
Tel/Fax +86-27-85889369
Mobile:  +8618660874450
                +8613886883411

                +8615117073372
                +8618858011948
                +8613707139057        
​Copyright © Chengli Special Automobile Co., Ltd  All Rights Reserved.